{"created":"2023-06-19T06:56:52.651781+00:00","id":212,"links":{},"metadata":{"_buckets":{"deposit":"b42b8887-34ef-40f5-9be3-087da096cf2e"},"_deposit":{"created_by":13,"id":"212","owners":[13],"pid":{"revision_id":0,"type":"depid","value":"212"},"status":"published"},"_oai":{"id":"oai:rctoyota.repo.nii.ac.jp:00000212","sets":["30"]},"author_link":["139","234"],"control_number":"212","item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-10","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"5","bibliographicPageEnd":"50","bibliographicPageStart":"46","bibliographicVolumeNumber":"25","bibliographic_titles":[{"bibliographic_title":"感染防止"}]}]},"item_10001_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"【目的】開放式気管吸引処置(以下気管吸引処置)がなされる患者の療養環境周辺が、どの範囲に飛散汚染するかを実験的に推定することを目的とした。【方法】看護師を対象として吸引後に生じる模擬痰が飛散したベッドシーツにおける点状の汚染量の把握とATP(アデノシン三リン酸)量を汚染の指標として、ベッドシーツやベッド柵などへの飛散量を測定して比較した。【結果】ベッドシーツにおいて飛散した点状汚染の最も多かったのは模擬気管口に隣接した左右30cm×30cmの区画であった。ATP量の比較では、ベッドシーツへの汚染が最も多かった。【考察】吸引操作では、模擬気管口の周辺30cm×30cmの区画における汚染は強いことが推定された。吸引操作は繰り返し行われることから日常的に飛散汚染で暴露していることが示唆された。","subitem_description_language":"ja","subitem_description_type":"Abstract"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"感染防止研究会"}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"感染防止研究会"}]},"item_10001_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10410516","subitem_source_identifier_type":"NCID"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"13409921","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"東野, 督子","creatorNameLang":"ja"},{"creatorName":"HIGASHINO, Tokuko","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{"nameIdentifierURI":""},{}]},{"creatorNames":[{"creatorName":"石黒, 千映子","creatorNameLang":"ja"},{"creatorName":"ISHIGURO, Chieko","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{"nameIdentifierURI":""},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2016-10-01"}],"displaytype":"detail","filename":"東野:気管吸引操作と(感染防止25(5)p46-50).pdf","filesize":[{"value":"182.1 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"気管吸引操作と環境への汚染に関する調査研究","url":"https://rctoyota.repo.nii.ac.jp/record/212/files/東野:気管吸引操作と(感染防止25(5)p46-50).pdf"},"version_id":"df6c1bd9-8a28-4882-8987-054dc70dd014"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"喀痰","subitem_subject_scheme":"Other"},{"subitem_subject":"環境汚染","subitem_subject_scheme":"Other"},{"subitem_subject":"環境モニタリング","subitem_subject_scheme":"Other"},{"subitem_subject":"機器の汚染","subitem_subject_scheme":"Other"},{"subitem_subject":"吸引術","subitem_subject_scheme":"Other"},{"subitem_subject":"寝具とリネン","subitem_subject_scheme":"Other"},{"subitem_subject":"ベッド","subitem_subject_scheme":"Other"},{"subitem_subject":"気管内吸引","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト","subitem_subject_scheme":"Other"},{"subitem_subject":"看護","subitem_subject_scheme":"Other"},{"subitem_subject":"Adenosine Triphosphate","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"気管吸引操作と環境への汚染に関する調査研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"気管吸引操作と環境への汚染に関する調査研究","subitem_title_language":"ja"}]},"item_type_id":"10001","owner":"13","path":["30"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2016-10-01"},"publish_date":"2016-10-01","publish_status":"0","recid":"212","relation_version_is_last":true,"title":["気管吸引操作と環境への汚染に関する調査研究"],"weko_creator_id":"13","weko_shared_id":-1},"updated":"2023-07-26T08:10:31.715086+00:00"}